Wednesday, October 10, 2012

Kudos to Lenovo / IBM service

Since over a year I'm the happy owner of a Lenovo Thinkpad T520, and on the whole I can only recommend it as a power-user Linux machine. Excellent for day-to-day work as well as measurement data processing, Gentoo runs on it nicely, and with a Core i5 and 8G RAM even app-office/libreoffice has lost its horrors. Since I'm travelling often and also tend to working on the weekend in one of these beautiful cafes in the historic city centre of Regensburg, I'm relying on it a lot. So when I bought it, I added a ThinkPlus warranty upgrade to the basket, according to the paperwork 3 years next-workday on-site service for 87€.
The surprise of last friday evening was the laptop's complete refusal to boot. Just some blinking of the power indicator, nothing else. No idea what caused it... Anyway. I started worrying, even took out the harddrive and replaced it with a blank one I had lying around, and prepared myself for being laptop-less for a while.
Called service tuesday morning. A technician called me back wednesday morning, and came along wednesday afternoon. After about 90min, the laptop was completely disassembled, reassembled with a new mainboard and the original hard drive, and worked flawlessly. Yay! One happy customer.

Monday, October 1, 2012

New dilution refrigerator arriving!

We've been waiting patiently for this for quite some time, but now, it seems, our brand new Oxford Instruments Kelvinox HA400 dilution refrigerator is about to arrive in our lab. Yay! The first two boxes are already there... and another seven, I've been told, are on the way from the UK.
The first picture on the right shows the main insert assembly, which is later dipped into a liquid helium-4 bath for precooling. (Remember, we're going to the millikelvin range, so liquid helium-4 at 4.2K is pretty hot.) The lower, copper-coated part of the insert is a vacuum can, the so-called IVC, and inside there, thermally shielded by the vacuum, all the ultra-low temperature cooling goes on. The lower end of this can finally with a slender tail fits into the 3" central bore of a small superconducting magnet. Some experiments which do not need a magnetic field can be conducted directly at the last cooling stage, others are mounted at the center of this tail, i.e. in the center of the magnet.
The second picture shows the actual main cooling circuit, the so-called dilution unit, which will be mounted into the vacuum can when the system is undergoing final assembly. The cooling process is based on the quantum mechanical properties of liquid helium-3 and helium-4 at temperatures below 0.9K; this particular model can reach temperatures down to 7mK (yes that's 0.007 degrees above the absolute zero of temperature). A simplified description of the process can be found on the dilution refrigerator wikipedia page. We'll post some more and nicer pictures once the final assembly is on the way...

Sunday, August 5, 2012

Lab::Measurement 3.10

Since we've got several interesting measurements running in the lab at the moment, our scripts are receiving a lot of attention. Which means we can already release a new feature (and bugfix) version, Lab::Measurement 3.10. Packages are on CPAN (and in Gentoo portage); you'll find the major changes listed below. Cheers!

Lab::Bus and Lab::Connection classes

  • Initial support for the USBtmc Linux kernel driver
  • GPIB (i.e. IEEE-488) termination characters are now handled identically in LinuxGPIB and VISA_GPIB
  • New VISA_RS232 connection which takes all arguments as RS232

Lab::Instrument classes

  • HP34420A nanovoltmeter re-added
  • Many improvements in the Oxford Instruments ITC503 driver
  • Re-named the Oxford Instruments IPS12010 driver to OI_IPS
  • New driver: Trinamic PD-110-42 stepper motor
  • New driver: Agilent U2000 rf power sensor

Lab::Measurement classes

  • Started refactoring the keyboard handling code

Thursday, July 26, 2012

NJP accepted: Magnetic damping of a carbon nanotube NEMS resonator

There's very good news- our first Regensburg article on carbon nanotube nano-electromechanical systems, "Magnetic damping of a carbon nanotube NEMS resonator", was just accepted for publication by New Journal of Physics.
Let me give you a short introduction what we've been working on here. A very exciting discovery some time ago was that at low temperatures (T<0.1K) mechanical resonators made from single-wall carbon nanotubes show very large quality factors Q. That means, once vibrating they store energy for a long time, and the vibration decays only very slowly - a piano string with a similar Q would sound for over five minutes after hitting the key! 
Now this has all sorts of interesting side effects. It's so easy to keep the vibration going that it basically runs on its own once a current passes through the device and some prerequisites are given. The device switches between different stability regions, and the usually very predictable transport spectroscopy pattern of a carbon nanotube quantum dot gains strange shapes and sharp edges.
Amazingly, as soon as you apply a magnetic field, this effect is all gone again, and the transport spectrum becomes regular. The overall current does not change significantly, so our tunnel rates should not be influenced too much by the magnetic field. Which means, according to the theory, that our magnetic field has to tune the second available "knob", the quality factor Q of the mechanical vibration. And indeed if we now drive the system with a radio-frequency signal, we see that the resonance becomes broader in frequency in a high magnetic field - the quality factor decreases.
So what's the damping mechanism? Actually, that is pretty straightforward. In a magnetic field, the vibrating nanotube acts as an ac voltage source, generating a small voltage the same way as a macroscopic ac generator. In addition, high-frequency signals can be transmitted capacitively between, say, parallel cables. Consequently a small ac current flows across a parasitic circuit with a ~100kOhm resistance somewhere, which dissipates energy; the resulting upper limit for Q scales with 1/B2. We can compare this model with our observed Q(B), and see a very nice agreement. Effectively, we've built the world's smallest eddy current brake!

"Magnetic damping of a carbon nanotube NEMS resonator"
D. R. Schmid, P. L. Stiller, Ch. Strunk, and A. K. Hüttel
accepted for publication by New Journal of Physics; arXiv:1203.2319 (PDF)

Monday, July 16, 2012

Gentoo in c't magazine

For the German speakers around here, today's edition of c't magazine (that's the company that people from UK/USA may know as "The H") includes an introductory article on Gentoo Linux: "Made to measure - Gentoo Linux: source code and rolling releases". So, go to your newsagent and grab it while it's hot! :)

Thursday, July 12, 2012

Lab::Measurement 3.00 released

I'm happy to be able to announce a first real release of the Lab::Measurement Perl package, providing a platform for measurement control with Perl.

Lab::Measurement is based on the packages Lab::VISA, Lab::Instrument, and Lab::Tools started by Daniel Schröer in 2005. Many people have contributed in the meantime, amongst others in roughly historical order Daniela Taubert, David Kalok, Florian Olbrich, and Alois Dirnaichner. The efforts of the last year have focussed on a general modularization, originally driven by a certain frustration with National Instruments NI-VISA support on Linux. Now, the hardware driver backend can be exchanged transparently, making measurements both with NI-VISA and with e.g. LinuxGPIB or the operating system serial port drivers on Linux and Windows possible.
Since VISA does not form a central part or even requirement anymore, the original use of Lab::VISA as name for the entire package became impractical, and we've decided to switch to Lab::Measurement instead. As version numbers of all components should still increase monotonously, our first release of the code rewrite then actually ended up as Lab::Measurement 3.00.

For downloads and documentation, including installation instructions for Linux and Windows and examples, visit the homepage of the package, http://www.labmeasurement.de/. Of course, if you're using Gentoo, the package is readily available in the main portage tree as dev-perl/Lab-Measurement.

Not all device drivers have been ported to the new internal architecture so far, but work is progressing swiftly. In the Regensburg nanophysics groups, we're using the new code already all the time in measurements at three different cryogenic setups. More drivers, bugfixes, and improvements are present in Git master. If you're willing to hack, I can only recommend that you give it a try. Contributors are always welcome; feel free to clone our git repository on Gitorious.

Saturday, June 16, 2012

Top position in condensed matter physics

While everyone in the German research landscape was following the selection of the "Elite Universities" during the last days, we've had some remarkable news here ourselves: the DFG, which awards all the federal research funding in Germany, published the statistics of the last years. The full "Förderatlas" can be found on the website of the DFG, here's the interesting bit (self-made translation):



In the comparison of all German universities, Regensburg managed to get to rank 4 in physics in total, and to a clear number one position in the field of condensed matter physics! Actually we've gotten more funding in CM than TU München and LMU München together! Now if that's not something to celebrate...
Summarizing, now you know where to go for top-notch physics research. :)